MIC-KEY* Low Profile FEEDING TUBE KITS – Gastric, GastroJejunal and Jejunal access
Avanos has the MOST comprehensive low-profile feeding tube portfolio on the market to meet your clinical needs.
ExploreMIC* FEEDING TUBES – Gastric, Jejunal and Gastrojejunal access
Avanos has the MOST comprehensive feeding tube portfolio on the market to meet your clinical needs.
ExploreMIC-KEY* Low Profile FEEDING TUBE KITS – Gastric, Gastro-Jejunal and Jejunal access
MIC-KEY* G FEEDING TUBES
Fit for All Stages – From Your Youngest Patient to Your Oldest Patient
The MIC-KEY* G-TUBE is a step up from conventional gastrostomy feeding tubes. The MIC-KEY* G Feeding Tube is unobtrusive and easy to conceal, making it an ideal feeding tube for a wide variety of patients. Our Low-Profile Balloon Retained G Tube:
- Is used by more clinicians for patients than any other brand1
- Is backed by the largest body of clinical evidence2
- Has high patient satisfaction with low adverse events such as granulation
MIC-KEY* G Feeding Tube:
- Sits at skin level
- Easy to conceal
- Limited interference with clothing
- Various sizes for paediatrics through to adult
- Helps patients to enjoy life to the fullest
Resources
MIC-KEY* GJ FEEDING TUBES
Better Jejunal Feeding with Gastric Decompression
The MIC-KEY* Gastric-Jejunal (GJ) Feeding Tube provides for simultaneous gastric decompression drainage and delivery of enteral nutrition into the distal duodenum or proximal jejunum. It is indicated for use in patients who cannot absorb adequate nutrition through the stomach, who have intestinal motility problems, gastric outlet obstruction, severe gastroesophageal reflux, are at risk of aspiration, or in those who have had previous esophagectomy or gastrectomy. The MIC-KEY* GJ Feeding Tube sits at skin level and comes in a variety of sizes and lengths to help ensure an accurate fit – 14, 16, 18 and 22 Fr outer diameter with multiple lengths. Can be used as initial placement or replacement into an existing stoma tract. Surgical, radiologic or endoscopic placement.
Resources
MIC-KEY* J FEEDING TUBES
Low-Profile Jejunal Feeding
The MIC-KEY* J Feeding Tube is indicated for patients requiring jejunal feeding only, but who want an inconspicuous external segment. Indicated for initial placement as well as a replacement device. With an external bolster designed like the widely prescribed MIC-KEY* G Feeding Tube, specific features include:
- Medical-Grade Silicone Construction
- Low-Profile Design
- Tapered Distal Tip
- Inflatable Silicone Internal Retention Balloon
- Distal Tip Recessed at 5ml
- Proximal Anti-Reflux Valve
- SECUR-LOK* Extension Set Connector Mechanism
- Trimmable Distal Tip
- Radiopaque Stripe
- Wide Variety of Extension Sets Available
Resources
MIC-KEY* EXTENSION SETS
Avanos offers a complete range of MIC-KEY* extension sets for MIC-KEY* G-, J- and GJ-tubes, allowing continuous feeding, bolus feeding or the administration of medication.
The MIC-KEY* Extension Set with SECUR-LOK* and Safety Ring:
- fits excellently into the MIC-KEY* feeding port, opening or unlocking the anti-reflux valve;
- results in less risk of leakage due to the designed and tested compatibility;
- the safety ring helps prevent inadvertent connection to intravenous lines.
STOMA MEASURING DEVICE
The MIC-KEY* Over the-Wire Stoma Measuring Device assists in determining proper feeding tube stoma length of all MIC-KEY* low profile G, GJ and J feeding tubes.
MIC* FEEDING TUBES – Gastric, Jejunal and Gastrojejunal access
MIC* G and MIC* G Bolus Feeding Tubes and Kits
Giving caregivers a choice… The MIC* Gastrostomy feeding tubes include two ENFit® gastric access ports, one for continuous feed access and one for medication access. The MIC* G Bolus feeding tubes include one ENFit® gastric access port.
MIC* G and MIC* G Bolus tubes are available in units of 2 or individually as part of a convenient replacement kit. All MIC* G and MIC* G Bolus tubes feature a recessed distal tip from Size 14 Fr and above. The 12 Fr tubes have a low volume balloon.
Resources
MIC* GJ FEEDING TUBES
Better Jejunal Feeding with Gastric Decompression
The MIC* Gastric-Jejunal (GJ) Feeding Tube provides for simultaneous gastric decompression drainage and delivery of enteral nutrition into the distal duodenum or proximal jejunum. It is indicated for use in patients who cannot absorb adequate nutrition through the stomach, who have intestinal motility problems, gastric outlet obstruction, severe gastroesophageal reflux, are at risk of aspiration, or in those who have had previous esophagectomy or gastrectomy. The MIC GJ Feeding Tube comes in a variety of sizes and lengths to help ensure an accurate fit – 14, 16, 18 and 22 Fr outer diameter with multiple lengths. It has a weighted jejeunal section. It can be used as initial placement or replacement into an existing stoma tract. Surgical, endoscopic or radiologic placement kits available.
Resources
MIC* J FEEDING TUBES
The MIC* J Feeding Tube is indicated for patients requiring jejunal feeding only. The distal tip can be trimmed to suit individual patient needs. Specific features include:
- Medical-Grade Silicone Construction
- Tapered Distal Tip
- Inflatable Silicone Internal Retention Balloon
- Distal Tip Recessed at 5ml
- Not formulated with Natural Rubber Latex nor DEHP
- Radiopaque Stripe
- Universal Feeding Port Connector
- SECUR-LOK* External Retention Ring
Resources
MIC* JEJUNOSTOMY TUBE
The MIC* Jejunostomy Feeding Tube is indicated for patients requiring jejunal feeding. It is surgically placed directly into the small bowel, using the Witzel Tunnel technique for secure placement and to help minimise leakage. Featuring a large 9Fr internal diameter to help prevent clogging, specific features include:
- Medical-Grade Silicone Construction
- Trimmable Distal Tip
- Suture Wings
- Large 9Fr Internal Diameter
- Radiopaque Stripe
Percutaneous Endoscopic Gastrostomy feeding tubes
CORFLO* PEG
Traction removable Polyurethane PEG tubes and accessories
Range of Push and Pull PEG tube kits to suit clinician preference. Replacement feed port connector accessories ensure the feeding tube can continue to be used without intervention. CORFLO* Jejunal extension tube (for use with CORFLO* PEG Tubes) facilitate jejunal access via a pre-existing CORFLO* PEG tube.
Resources
MIC* PEG
Silicone PEG tubes
The MIC* PEG KIT is designed for placement convenience. Available in PULL and PUSH version. Range of Push and Pull PEG tube kits to suit clinician preference. Replacement feed port connector accessories ensure the feeding tube can continue to be used without intervention.
- Medical-Grade Silicone Construction
- SECUR External Retention Ring
- Universal and Bolus Feeding Port Connectors with integrated Medication Port
- Not formulated with Natural Rubber Latex nor DEHP
- Radiopaque Stripe and full opaque Bumper
- Tubing Clamp
- Traction removable (except Fr 14)
- ETO Sterilised
ENTERAL ACCESSORIES
CLOG ZAPPER* ENTERAL FEEDING TUBE DECLOGGING SYSTEM
Clearing Blockages in Enteral Feeding Tubes
Our patented CLOG ZAPPER* is a pre-mixed, pre-measured, pre-loaded system designed to break up formula clogs in enteral feeding devices.
CLOG ZAPPER* combines an “enzyme cocktail,” acids, buffers, antimicrobial agents, and metal inhibitors in an all-inclusive, ready-to-use system. The ingredients all work together to loosen, break down and dislodge clogs. In clinical usage, CLOG ZAPPER* was successful in restoring patency to feeding tubes clogged with enteral formulas over 75% of the time.
MIC-KEY* & MIC* G, J, & GJ, FEEDING TUBE KITS
Extension Sets with ENFit® Connectors
No matter what connection type you select, Avanos supports all of your enteral feeding needs with:
- A comprehensive set of connectors for MIC-KEY* & MIC* Feeding Tubes and Accessories, including standard or ENFit®
- Consistent product availability from “Your Source for Enteral Feeding” for both connectors!
- Complete product training for a smooth transition when your facility is ready to convert to ENFit® connectors
MIC-KEY* EXTENSION SETS
Avanos offers a complete range of MIC-KEY* extension sets for MIC-KEY* G-, J- and GJ-tubes, allowing continuous feeding, bolus feeding or the administration of medication.
The MIC-KEY* Extension Set with SECUR-LOK* and Safety Ring:
- fits excellently into the MIC-KEY* feeding port, opening or unlocking the anti-reflux valve;
- results in less risk of leakage due to the designed and tested compatibility;
- the safety ring helps prevent inadvertent connection to intravenous lines.
INTRODUCER KIT
MINIMALLY INVASIVE MEETS MAXIMUM EASE
The Avanos Introducer Kit avoids a second invasive procedure by faciliating the initial placement of a MIC, MIC-KEY G,J or GJ balloon retained feeding tubes. The Introducer Kit delivers all the essential tools for an efficient, secure and less invasive placement. Designed for Fluoroscopic, Endoscopic or Laparoscopic placement. The kit offers:
- Lowered risk for surgical and post-op complications that other procedures may pose (e.g., longer hospital stay, punctured colon, tissue damage, etc.)3
- Tools specifically designed for visual and surgical accuracy
- Sterilised Saf-T-Pexy needles to perform gastropexy, safety introducer needle, haemostat, J-guide wire/seeking catheter, safety scalpel and more.
- Flexibility as adjunctive or primary procedure [MIC* or MIC-KEY* G, J or GJ Feeding Tube placement (12-20 Fr)]
- Easy access to the essential tools in one convenient kit
Resources
Webinar
Direct Puncture Gastrostomy in Children – Dr. Bontems
CORFLO* NASOGASTRIC & NASOINTENSTINAL FEEDING TUBES
CORFLO* NASOGASTRIC & NASOINTENSTINAL FEEDING TUBES
The Avanos CORFLO* NG/NI feeding tubes are available in a wide variety of adult, pediatric and neonatal sizes. Their polyurethane construction makes them excellent for long-term intubation and offers a larger lumen than PVC tubes and Silicone tubes of the same French size.
Designed to prevent feeding tube misconnections, CORFLO* NG/NI feeding tubes with ENFit® connectors feature a clear connector housing for visual inspection of connection with administration sets, as well the inspection of cleanliness before, during and after use. In line with National Patient Safety Agency guidance CORFLO* NG/NI tubes are fully radiopaque along their entire length, are CE marked and have external visual length markings.
Video Resources
CORGRIP* NG/NI TUBE RETENTION SYSTEM & CONVENIENCE KITS
CORGRIP* NG/NI TUBE RETENTION SYSTEM
Keeping Feeding Tubes In Place.
Inadvertent dislodgement of feeding tubes has been reported with a prevalence of up to 63%. Tube displacement can lead to Increased risk of aspiration, interruption in nutritional support, skin breakdown, radiographic exposure through verification of tube reinsertion. CORGRIP* Nasogastric/Nasointestinal Tube Retention System can result in(1,2): Lower rates of tube dislodgement, decrease use of imaging, achieve higher percentage of target feed delivery, and potentially lower patient distress. Designed to prevent inadvertent removal or displacement of feeding tubes in adult patients, CORGRIP* Nasogastric/Nasointestinal Tube Retention System is indicated for use with enteral feeding tubes of 8 FR and greater and NG decompression, suction and drainage tubes up to 18 FR.
Use of the CORGRIP* system can increase a patient’s caloric intake and may help to avoid unnecessary escalation to percutaneous endoscopic gastrostomy feeding or intravenous nutrition.
The CORGRIP* System components include:
- Water-soluble Lubricant
- White Retrieval Catheter
- Yellow Retrieval Catheter
- Opening Device
- SSL* (Slot-Slide-Lock) Camp
Video Resources
ENFit compatible accessories
Enteral Syringes
Single use ENFit® compatible syringes
1ml, 2.5ml and 5ml ENFit® low dose to ensure dose accuracy. 10ml, 20ml and 60ml standard ENFit® syringes.
Enteral Accessories
A wide range of ENFit® drawing straws, syringe caps, bottle adaptors extension tubing and more to facilitate the handling of enteral fluids prior to administration
aspHirate pH Indicator Strips
Testing human gastric aspirate via a feeding tube
Results from an audit examining the viability of pH indicator strips for nasogastric tube placement found participants made up to 11.15% errors reading the strips and reported anxiety in their use.5
Study results supported the development of new pH indicator strips that are more usable and less likely to be misread.5
INNOVATING THE STANDARD – IMPOVING PATIENT SAFETY
• Easy to read at critical clinical decision values
• Accuracy supported with independent test data
• Adjusted to read water at pH 7
• Unique scale for accurate documentation
• Unique single scale printed lengthwise for ease of use
• Pictorial instructions alongside scale
• Unique 2 colour match
• Desiccant lid
References:
iData Research Inc., U.S. Market for Gastrointestinal Endoscopic Devices, iDATA_USGI12_RPT, February 2012
Pubmed indexed, published in English for on-label use, searched March 2013
Lynch A, et al . Aus J Otolayngol 2018;1:8
McGinnis C. Nutr Clin Pract. 2011;26(1);70-77
5 Ref BorsciS, et al. PLoS ONE 2017;12(11):e0189013
The MIC-KEY* & MIC* Feeding Tubes are indicated for use in patients who require enteral feeding. There are inherent risks in all medical devices; please refer to the product labelling for Indications, Cautions, Warnings and Contraindications. Please contact us at our number listed above or website for more important information.